Drainpipe Slope Measuring Inclinometer SEC-S011F-P
The inclinometer is a measuring instrument for inspecting the slope of drainpipes installed in inaccessible areas such as ceilings.
Drainpipes for gray water, sewage, air conditioning drains, etc. must have a certain slope.
If they are located behind the ceiling, you have to go up on a stepladder and place a bubble-type slope meter over the drainpipe and check at it using a mirror or something.
However, the drainpipe gradient measuring inclinometer introduced here can easily measure the gradient by placing the sensor part of the V-block shape under the drainpipe.
Features
01 Simply apply the sensor to the pipe for a one-shot measurement!
02 Easy operation without selecting the installation location or shape of the piping!
03 Simply apply the V-block (sensor) of the inclinometer to a drainpipe with a pole to digitalize the gradient.
04 Lower cost and higher accuracy than conventional measuring instruments!
Spec
General Specifications of Operation section | Main unit dimensions | W79✕ H117✕ D24 |
Power source | 2 AA batteries | |
Operating temperature range | 0 to 40°C (theoretical) | |
Operating humidity range | 25 to 85%RH (non-condensing) (theoretical) | |
Storage Temperature Range | -10 to 75°C | |
Storage Humidity Range | 20 to 90%RH (no condensation) | |
Atmosphere | No corrosive gas, no dust | |
Functional Specifications | Telescopic pole | 3-stage with a maximum length of 2 m and a minimum size of 89 cm |
Sensor section | Measured by placing an aluminum V-block on the piping from below | |
Operation Mode | Switch between measurement mode and user-set mode | |
ADJ | Relative angles are used for measurement. Assumes the angle at the set point is 0 degrees. | |
HOLD | Fixes the measured value. In this case, the displayed value blinks. | |
BACK LIGHT | Turns on the backlight.The backlight is automatically turned off after a set period of time. | |
Dead Battery Detection | The symbol (convex) blinks on the right side of the screen to indicate that the battery is dead. | |
Contrast adjustment | Title display is extended for 2 seconds at startup, followed by contrast adjustment. | |
Auto power off | Turns off the device when there is no button operation or angle change for a set period of time. |
Items | Power supply voltage (V) | Current Consumption with Backlight OFF (mA) | Current Consumption with Backlight ON (mA) |
---|---|---|---|
Current Consumption | 3 | 90 | 190 |
2.5 | 110 | 220 | |
2 | 140 | 300 |
Items | Min | Typ | Max | Units | Note | |
---|---|---|---|---|---|---|
General measurement | Supply voltage (V) | 2 | 3 | V | Assuming alkaline or nickel-cadmium battery | |
Measurable Angle | -1 | - | 100/100 | gradient | *Sensor V-block removed from channel | |
Angle resolution | - | 0.1/100 | - | gradient |